Overview
The A1000 is the premium AC drive from Yaskawa. It provides great operation reliability, environmental benefits, and energy savings as well as many other user-oriented operational features that make it a first-class choice.
- Encoderless operation of PM motors with full torque at zero speed
- Advanced Auto-Tuning functions to adjust automatically motor settings and analyze continuously changes during motor operation to achieve the highest machine performance
- Advanced energy-saving control technology which improves efficiency and machine productivity in combination with induction and synchronous motor operation
- Available with special features for a high-speed spindle, positioning, crane and hoist, electronic line shaft
Technical Details
- Input power supply
- 400 V
- Rated output current (HD)
- 260 A
- Rated output current (ND)
- 296 A
- Overload Tolerance (ND)
- 120% for 60 s
- Overload Tolerance (HD)
- 150% for 60 s
- Max. applicable motor power (HD)
- 132 kW
- Max. applicable motor power (ND)
- 160 kW
- Input power phases
- 3-phase
- EMC filter
- x No
- Motor type
- Permanent magnet motor, Induction motor
- Encoder
- x No
- Standards compliance
- cUL, CE, RoHS, UL, UKCA
- Regenerative Capacity
- x No
- Ambient Temperature (Min)
- -10 °C
- Ambient Temperature (Max)
- 40 °C
- Ambient Temperature (Max) with Derating
- 50 °C
- Max. Humidity (non-condensing)
- 95 %
- Max. Altitude (without Derating)
- 1000 m
- Max. Altitude (with Derating)
- 3000 m
- Height
- 800 mm
- Width
- 500 mm
- Depth
- 350 mm
- Weight
- 102 kg
- Cooling method
- Air cooling, Coldplate
- Enclosure
- IP00
- Environmental Specifications
- Standard
- Analog Input
- 3
- Analog Output
- 2
- Digital Input
- 8
- Digital Output
- 4
- Safety Level
- SIL2
- Performance Level
- PL d
- Torque Control
- Standard
- Braking transistor
- External
- Motor Thermal Protection
- Standard
- Max Output Frequency
- 400 Hz
Downloads
Name | |||
A1000 AC Drives | EU Declaration of Conformity
Low Voltage Directive, Electromagnetic Compatibility Directive, Machine Directive, RoHS, Certificate No. EZZ024521<1> issued June 12, 2023 Certification | Swedish, Spanish, Slovenian, Polish, Italian, German, French, Finnish, English, Dutch, Danish, Czech |
Certification | Swedish, Spanish, Slovenian, Polish, Italian, German, French, Finnish, English, Dutch, Danish, Czech | |
EPLAN for A1000 Standard Inverter Drives
Data package includes all modells EPLAN | English |
EPLAN | English | |
A1000 | Technical Manual
SIEP-C710616-27J Technical documentation | English |
Technical documentation | English | |
A1000 | Technical Manual
SIGP-C710616-27F Technical documentation | German |
Technical documentation | German | |
A1000 | Quick Start Guide
TOEP-C710616-27I Technical documentation | English |
Technical documentation | English | |
A1000
Quick Start Guide, TOEP-C710616-27D Technical documentation | German |
Technical documentation | German | |
A1000
Quick Start Guide, TOFP-C710606-27D Technical documentation | French |
Technical documentation | French | |
A1000
Quick Start Guide, TOIP-C710616-27D Technical documentation | Italian |
Technical documentation | Italian | |
YASKAWA Variador CA A1000
Quick Start Guide, TOSP-C710616-27D Technical documentation | Spanish |
Technical documentation | Spanish | |
A1000
Quick Start Guide, TOYP-C710616-27D Technical documentation | Czech |
Technical documentation | Czech | |
A1000
Quick Start Guide, TOWP-C710616-27D Technical documentation | Polish |
Technical documentation | Polish | |
A1000
Quick Start Guide, TOWP-C710616-27D Technical documentation | Turkish |
Technical documentation | Turkish | |
A1000 IP54 Ready
Quick Start Guide, TOEP-C710616-97A Technical documentation | English |
Technical documentation | English | |
A1000 IP54 Ready
Quick Start Guide, TOGP-C710606-97A Technical documentation | German |
Technical documentation | German | |
A1000 IP54 Ready
Quick Start Guide, TOFP-C710606-97A Technical documentation | French |
Technical documentation | French | |
A1000 IP54 Ready
Quick Start Guide, TOIP-C710616-97A Technical documentation | Italian |
Technical documentation | Italian | |
A1000 IP54 Ready
Quick Start Guide, TOSP-C710616-97A Technical documentation | Spanish |
Technical documentation | Spanish | |
A1000 IP54 Wall Mount
Quick Start Guide, TOEP-C710616-96A Technical documentation | English |
Technical documentation | English | |
A1000 IP54 Wall Mount
Quick Start Guide, TOGP-C710616-96A Technical documentation | German |
Technical documentation | German | |
A1000 IP54 Wall Mount
Quick Start Guide, TOFP-C710616-96A Technical documentation | French |
Technical documentation | French | |
A1000 IP54 Wall Mount
Quick Start Guide, TOIP-C710616-96A Technical documentation | Italian |
Technical documentation | Italian | |
A1000 IP54 Wall Mount
Quick Start Guide, TOSP-C710616-96A Technical documentation | Spanish |
Technical documentation | Spanish | |
A1000 IP23/54 Floor Standing Panel
Quick Start Guide, TOEP-C710616-88A Technical documentation | English |
Technical documentation | English | |
CAD for A1000 Standard Inverter Drives
CIMR-AC4A0296AAA, 400V 296A 160kW, Data package CAD/CAE | |
CAD/CAE |